- 19 -
If some of the above VCO control voltage readings are < 1.0 V, or some
of them are > 7.5 V, you may be able to shift the entire set of readings so that
they are all within the 1.0 to 7.5 V range. Switch to the band (and frequency)
that had the highest or lowest voltage, then adjust L30 to bring that reading
into range. Then re-measure all of the voltages to make sure they're in range.
Δ
If you have some voltages that are < 1.0 V and others that are > 7.5 V,
you may have installed the wrong value at one or more of the VCO capacitors
(C71 - C74) or varactor diodes (D21 - D26). Another possibility is that T5 has
the wrong number of turns or that you installed the wrong type of slug-tuned
inductor at L30. ALTHOUGH MOST LIKELY YOU EITHER FORGOT
TO CHANGE THE EXTENDED VFO RANGE (D19) SECONDARY
MENU SETTING TO “YES” (AS DESCRIBED ON PAGE 60), OR YOU
DID A HARD FACTORY RESET WHICH UNDID THIS CHANGE! If
you change any of these components OR THE (D19) SECONDARY MENU
SETTING, you need to repeat the VCO alignment procedure.