Elecraft KIO2 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Kommunikationszubehör Elecraft KIO2 herunter. Elecraft KIO2 User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 10
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
1
E L E C R A F T K I O 2 P R O G R A M M E R ' S R E F E R E N C E
Rev. E, Feb. 3, 2004
Change History
Rev. E, Feb.. 3, 2004 (In conjunction with K2 MCU firmware rev. 2.04)
Release 2.04 K2 firmware adds 60-meter support (requires K60XV option), 6 transverter bands (vs. 3), low-
level transverter I/O support (requires K60XV), and two new scanning modes. Most of these features are
accessible via RS232 commands. See the latest K2 Rev 2 Firmware instruction sheet for full details.
The UP and DN commands can now be used to scroll or change parameter values in the menu. This should be
especially useful as a way to automate BFO and filter setups in C A L F I L . Previously, there was no way to
vary the BFO or filter parameters via RS232 commands.
Added TQ (transmit query) command, GET only. Returns 0 if the K2 is in receive mode, 1 if in transmit mode.
This is the preferred way to check RX/TX status.
Added SW80 and SW81 commands. These emulate 2-button combinations
A F I L +S P L I T (KDSP2 notch
filtering on/off) and
A F I L +R E C (KDSP2 noise reduction on/off). Displays N O T I N S T on the K2 LCD if
the KDSP2 firmware revision in use does not support the command, and an all-blank display if used with a
KAF2.
Improved RC command (RIT Clear). This command previously had no effect during transmit. In the new
firmware revision, the occurrence of an RC command during transmit sets a clear_pending flag, so that the
RIT/XIT offset can be cleared as soon as the K2 returns to receive mode, however briefly. The effect of the RC
command will be delayed by some amount, varying with the keying speed and whether the operator un-keys
briefly between characters. Also, an unknown command indication will still be returned by the K2 in this case
(?;).
Rev. D, May 15, 2002
The description of mode AI2 incorrectly stated that the radio would send back an MD response when the mode
button is pressed. The radio actually sends an IF response, which includes mode data.
Release 2.02E of the K2 firmware adds a new field to the extended form of the PC (power control) SET
command (page PC (Power Output Level; GET/SET)). This can be used with the K2/100 to select QRP (0.1-
15.0 W) or QRO (1-110 W) ranges.
Seitenansicht 0
1 2 3 4 5 6 7 8 9 10

Inhaltsverzeichnis

Seite 1 - Change History

1E L E C R A F T K I O 2 P R O G R A M M E R ' S R E F E R E N C E Rev. E, Feb. 3, 2004Change HistoryRev. E, Feb.. 3, 2004 (In conjunction wit

Seite 2 - Command Set Overview

10Table 4 SW command values for emulation of two-switch combinations.Function Switch Combination <nn>FINE RIT on/off XFIL RIT 33Direct Freq. En

Seite 3 - Busy Indication

2Command Set OverviewThe K2 firmware provides a wide range of remote control commands1. A brief description of each commandappears in Table 1, and ful

Seite 4 - Meta-commands: AI and K2

3Command FormatCommands sent from the computer to the K2 are considered either GETs or SETs. GET commands are used by thecomputer to get information f

Seite 5 - Command Reference

4Remote Control of PotentiometersKeyer speed, power output, and RIT/XIT offset are controlled by their potentiometers or by the computer,whichever was

Seite 6

5Command ReferenceThis section describes all K2 GET, SET and RSP (response) command formats. Unless otherwise noted, the GETformat is just the two let

Seite 7

6Annunciator data: This field is a single byte whose value is between 0x80 and 0xFF. Bit 7 is always 1. The other7 bits indicate the on/off states of

Seite 8

7GT (AGC Time Constant; GET/SET)Basic SET/RSP format: GTnnn; where n is 002 for fast AGC and 004 for slow AGC.Extended SET/RSP format: GTnnnx; wher

Seite 9

8LK (VFO Lock; GET/SET)SET/RSP format: LKn; where n is 0 (VFO unlocked) or 1 (locked).MD (Operating Mode; GET/SET)SET/RSP format: MDn; where n is

Seite 10 - XT (XIT Control; GET/SET)

9RT (RIT Control; GET/SET)SET/RSP format: RTn; where n is 0 (RIT OFF) or 1 (RIT ON).RU (RIT Offset Up 10 Hz, or FINE RIT Offset Up One Unit; SET onl

Verwandte Modelle: K2

Kommentare zu diesen Handbüchern

Keine Kommentare